AS-Interface gateway VBG-ENX-K20-DMD-EV - фото 1 - id-p95198742
Характеристики и описание

Техническая спецификация в PDF  

Описание оборудования

EtherNet/IP + MODBUS/TCP com unit with data decoupling, double master for 2 AS-Interface networks

General specifications

AS-Interface specificationV3.0
PLC-Functionalityactivateable
Duplicate address detectionfrom AS-Interface slaves
Earth fault detectionintegrated
EMC monitoringintegrated
Diagnostics functionExtended function via display
UL File NumberE223772 only from low voltage, limited energy source (SELV or PELV) or listed Class 2 source

Indicators/operating means

DisplayIlluminated graphical LC display for addressing and error messages
LED AS-i ACTIVEAS-Interface operation normal; LED green
LED CONFIG ERRconfiguration error; LED red
LED PRG ENABLEautom. programming; LED green
LED POWERvoltage ON; LED green
LED PRJ MODEprojecting mode active; LED yellow
LED SER ACTIVEethernet active; LED green
LED U AS-iAS-Interface voltage; LED green
Button4
Switch SETSelection and setting of a slave address
OK buttonMode selection traditional-graphical/confirmation
Button MODEMode selection PRJ-operation/save configuration/cursor
ESC buttonMode selection traditional-graphical/cancel

Electrical specifications

Insulation voltage? 500 V
Rated operating voltagefrom AS-Interface 30 V DC
Rated operating current? 250 mA PELV

Interface 1

Interface type2 x RJ-45
ProtocolEtherNet/IP + MODBUS TCP/IP acc. to IEEE 802.3
supports device level ring protocol DLR
Transfer rate10 MBit/s / 100 MBit/s , Automatic baud rate detection

Interface 2

Interface typeRS 232, serial
Diagnostic Interface
Transfer rate19,2 kBit/s

Interface 3

Interface typeChip card slot

Connection

EthernetRJ-45
AS-Interfacespring terminals, removable

Directive conformity

Electromagnetic compatibility

Standard conformity

Electromagnetic compatibilityEN61000-6-2:2005, EN61000-6-4:2007
Degree of protectionEN60529:2000
AS-InterfaceEN62026-2:2013

Approvals and certificates

UL approvalAn isolated source with a secondary open circuit voltage of ? 30VDC with a 3A maximum over current protection. Over current protection is not required when a Class 2 source is employed.
UL mark does not provide UL certification for any functional safety rating or aspects of the device.

Ambient conditions

Ambient temperature0 ... 55 °C (32 ... 131 °F)
Storage temperature-25 ... 85 °C (-13 ... 185 °F)